103
12.Press the Menu button repeatedly until the information level ap-
pears on the display
✓ The standard display of i-01 is shown again.
SETTING THE ENABLE OR REDUCTION TIMES
On the HDG Compatronic control unit, you can set the enable or re-
duction times for the heating system. For each day of the week, you
can set a maximum of four different enable times or reduction times.
At the set reduction times, the boiler supply temperature is reduced.
Select the required level as follows:
1. Press the Enter button.
✓ The customer level is shown on the display.
2. Press the Down button until you reach the main menu 2-
Boiler.
3. Press the Enter button.
4. Repeatedly press the Down button until the parameter Enable
boiler 2-10 appears in the display.
✓ The display then shows Enable boiler 2-10.
5. Press the Enter button.
✓ The cursor flashes beneath the first day of the week Mo.
✓ The displayed value can now be changed.
6. Press the Plus or Minus button.
✓ The weekday is hidden or displayed.
7. Press the Down button.
✓ The cursor flashes beneath the next weekday.
8. Where no enable or reduction times are to be entered, hide the
days as described in step 4.
9. Press the Down button repeatedly until the cursor flashes under
the first time field ON 00:00.
✓ The cursor will flash under the first time field.
10.Press the Plus or Minus button.
✓ The value of the parameter is increased or decreased in incre-
ments of 15 minutes.
11.Configure the reduction times as described in step 8.
✓ The reduction times have been set.
12.Press the Enter button.
✓ The set reduction times have been confirmed.