8 Troubleshooting – Possible faults
176
F153 Safety circuit
Klixon feeding
syst.
Motor too hot
Cable not connected
Motor overload
Check current consumption
and connection
Check connection
F154 Safety circuit
Klixon dosage
Motor too hot
Cable not connected
Motor overload
Check current consumption
and connection
Check connection
F155 Safety circuit
Klixon delivery
syst
Motor too hot
Cable not connected
Motor overload
Check current consumption
and connection
Check connection
F160 Error external
feeding units
Terminals 32 + 33 not
bridged
External conveyor fault
Check terminals
F161 Klixon
Ash auger
Motor too hot
Cable not connected
Motor overload
Check current consumption
and connection
F162 Klixon
boiler cleaning
Motor too hot
Cable not connected
Motor overload
Check current consumption
and connection
F170 No connection to
GSM module
No telephone card in GSM
module
No GSM module available
Check GSM module
Cable not connected
Parameter 1-10 incorrectly
set
F171 GSM error, no
signal
No network or
SIM card
Radio network not available
Antenna connection
No SIM card in the modem
Insert SIM card
Connect antenna cable
F172 Modem not con-
nected
Cable at interface of PC (RS
232) or telephone box not
connected
Check cables
Fault is only activated during
remote maintenance with
modem
F180 Transport module
(IO21) wrong
version
Wrong transport module Exchange transport module
Notify HDG customer service
F181 Phase L2+L3 con-
nected
Wrong phase setting Notify HDG customer service
F200 CAN data trans-
fer wrong ID
System malfunction Notify HDG customer service
F201 CAN-BUS
error(read)
System malfunction Notify HDG customer service
No. Fault Cause Remedy
Table 8/1 - Faults