3 Mode of operation – Fuel quality requirements
37
NOMINAL THERMAL VALUE
DEPENDING ON WATER
CONTENT
The following table indicates the maximum nominal thermal value
depending on water content, in reference to the fuels approved for
the HDG Compact 25 - 80 in accordance with DIN EN 14961 "Solid
biofuels - fuel specifications and classes".
Wood chips
P31.5, M20, A1.0
(A1.5) or
Pellets A1, A2
Wood chips P45,
M25, A1.0 (A1.5)
Shaving briquet-
tes A1, A2, D60,
L50
Planing/saw sha-
vings A1, A2, M20,
A1.0 (A1.5)
HDG Compact 25 31 kW - - -
HDG Compact 35 31 kW - - -
HDG Compact 45 45 kW 43 kW, (42 kW) 43kW 42 kW, (40 kW)
HDG Compact 50 50 kW 48 kW, (47 kW) 48 kW 47 kW, (45 kW)
HDG Compact 65 65 kW 63 kW, (62 kW) 63 kW 62 kW (60kW)
HDG Compact 80 80 kW 78 kW, (77 kW) 78 kW 77 kW, (75 kW)
Table 3/7 - Max. nominal thermal value depending on water content