31 – 582 HEIDENHAIN Service Manual iTNC 530 HSCI
MP130.x y index of the machine parameters MP2xxx.y for the axes
Input: 0 to 12
PLC
RUN
MP131.x Y index of the machine parameters MP2xxx.y for the spindle(s) in operating mode 0
Input: 0 to 12
PLC
RUN
MP131.0 Index for the first spindle
MP131.1 Index for the second spindle
MP132.x Y index of the machine parameters MP2xxx.y for the spindle(s) in operating mode 1
Input: 0 to 12
PLC
RUN
MP132.0 Index for the first spindle
MP132.1 Index for the second spindle
MP210 Counting direction of position encoder output signals
Format: %xxxxxxxxxxxxxxxxxx
Input: Bit 0 to Bit 17 represent axis 1 to 18
0: Positive
1: Negative
REF
MP331.x Distance for the number of signal periods in MP332
Input: 0.0001 to +1.797693135E+308 [mm] or [°]
PLC
RUN
REF
MP332.x Number of signal periods for the distance in MP331
Input: 1 to +1.797693135E+308
PLC
RUN
REF
MP334.x Nominal increment between two fixed reference marks on encoders with distance-coded
reference marks
Input: 1 to 65 535
0: 1 000
PLC
RUN
REF
MP340.x Interpolation factor for external interpolation
Input: 0 to 99
0 = 1: No external interpolation
RESET
MP410 Assignment of axis keys IV, V and VI
Input:
Axis labels A/B/C/U/V/W/T
PLC
RUN
MP410.3 IV axis key
MP410.4 V axis key
MP410.5 VI axis key (only HR 5xx)
MP420.x Hirth coupling
Input: 0: No Hirth coupling
1: Hirth coupling
PLC
RUN
MP430.x Prescribed increment for Hirth coupling
Input: 0.0000 to 30.0000 [°]
PLC
RUN
MP708.x Traverse distance for acceleration-dependent backlash compensation
Input: 0.0001 to 1.000 [mm]
0: Function inactive
PLC
RUN
MP709.x Time constant for backlash compensation
Input: 1 to 1000 [ms]
PLC
RUN
MP710.x Backlash compensation
Input: –9.9999 to +9.9999 [mm] or [°]
PLC
RUN
MP711.x Height of peaks during circular movement (analog only)
Input: –1.0000 to +1.0000 [mm] (digital: 0)
PLC
RUN
MP712.x Compensation value per control loop cycle time
Input: 0.000000 to 99.999999 [mm] (digital: 0)
PLC
RUN
MP Function and input Software