Port: Access to the port used by IPC, the default is 80.
Update: Select one or more upgrade devices of the same type,
insert the U disk storing the upgrade package of the device into the NVR,
click "Upgrade", the system will find the upgrade package in the U disk
and display it, select the upgrade package, click "Upgrade ", Upgrade
IPC in batches at the same time.
Delete: In the list of added devices, select the channel to be deleted
and click the "Delete" button to delete all selected devices.
Enable H264+/H265+: Click to turn on H264 + / H265 + encoding for
all channels. To turn off H264 + / H265 + encoding, you can turn off the
channel H264 + / H265 + in the Parameters interface.
: Click and enter the channel setting interface, this functiton is the
same as” manual add”.
: Delete the current IPC from the device list.
Link: " " indicates that the connection is successful, and " "
indicates that the connection fails. If the connection fails, the
connection status will indicate the cause of the failure. If the password
is incorrect, the user password will be incorrect.
NOTE
An IPC can only be added once by the NVR.
When modifying IPs in batches, ensure that the user name and
password of all selected devices are the same.
If you modify IPs in batches, if the IP addresses conflict, the system
automatically skips conflicting IPs and re-assigns them incrementally.
After modifying the IP in batches, search for the remote device again.
The new IP address will be displayed in the list.
After you select a device to add a button, all devices will re-assign the IP
address. Use NOTE.
Adding mode can be set to "Manual" or "Plug and play" in the POE NVR,
which is not settable in the normal NVR.
Before using the upgrade function, copy the upgrade package
corresponding to the device to be upgraded to a USB flash drive and
insert the USB flash drive into the NVR.