EasyManua.ls Logo

HIKVISION DS-2TD6237-50H4L/W - Set Normal Mode

HIKVISION DS-2TD6237-50H4L/W
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version
View the version of current algorithm.
Reect Light Filter & Forkli Filter
Enable these funcons if there is strong reecve light from the sun or a forkli in the scene.
Or it may cause false alarm.
Note
These funcons and VCA funcon are mutually exclusive.
4. Oponal: Click Restart to restart the algorithm library.
5. Click Save.
3.3.2 Set Normal Mode
This funcon is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Conguraon → Temperature Measurement → Basic Sengs , and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to
Conguraon → Temperature Measurement → Advanced Sengs , and select Normal.
4.
Congure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is dierent.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the
connected alarm device.
5. Refer to Set Arming Schedule for
seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.