Version
View the version of current algorithm.
Reect Light Filter & Forkli Filter
Enable these funcons if there is strong reecve light from the sun or a forkli in the scene.
Or it may cause false alarm.
Note
These funcons and VCA funcon are mutually exclusive.
4. Oponal: Click Restart to restart the algorithm library.
5. Click Save.
3.3.2 Set Normal Mode
This funcon is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Conguraon → Temperature Measurement → Basic Sengs , and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to
Conguraon → Temperature Measurement → Advanced Sengs , and select Normal.
4.
Congure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is dierent.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the
connected alarm device.
5. Refer to Set Arming Schedule for
seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.