Reset paern scan path.
Delete the selected paern scan.
Note
If you need to delete all the paern scans, go to Conguraon → PTZ → Clear Cong , and
check Clear All Paerns, and click Save.
8.5 Set Linear Scan
The device can perform auto scan in seng area for re source detecon.
Steps
1. Go to
Conguraon → PTZ → Linear Scan .
2. Select the camera channel.
3. Zoom in and zoom out the camera to the appropriate zoom rao, and click Save Rao.
Note
Click Enable Saved Rao to set the camera to the saved zoom rao.
4. Check Enter Area Sengs.
5.
Set the le/right/up/down limits with the PTZ control panel, and click to conrm sengs.
6. Oponal: Click Clear to delete the saved scan area.
7. Click Save.
8. Click Call Linear Scan to start linear scan, and click Stop Linear Scan to stop linear scan.
Note
When seng the linear scan area, make sure the target area is both included in the opcal
channel and the thermal channel.
8.6 Set Limit
The device can only move within the limited range.
Steps
1. Go to Conguraon → PTZ → Limit .
2. Select Limit Type.
Manual Stops
It refers to the movement range limit when you control the device manually.
Scan Stops
It refers to the movement range limit when the device scans
automacally.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual
41