10.4.4 Exposure Sengs
Exposure is controlled by the combinaon of iris, shuer, and gain. You can adjust image eect by
seng exposure parameters.
Exposure Mode
Auto
The iris, shuer, and gain values are adjusted automacally.
You can limit the changing ranges of iris, shuer and gain by seng Max. Iris Limit, Min. Iris
Limit, Max. Shuer Limit, Min. Shuer Limit and Limit Gain for beer exposure eect.
Iris Priority
The value of iris needs to be adjusted manually. The shuer and gain values are adjusted
automacally according to the brightness of the environment.
You can limit the changing ranges of the
shuer and gain by seng Max. Shuer Limit, Min.
Shuer Limit and Limit Gain for beer exposure eect.
Shuer Priority
The value of shuer needs to be adjusted manually. The iris and gain values are adjusted
automacally according to the brightness of the environment.
You can limit the changing ranges of the iris by seng Max. Iris Limit, Min. Iris Limit and
Limit Gain for beer exposure eect.
Manual
You need to set Iris,
Shuer, and Gain manually.
Slow Shuer
The higher the slow shuer level is, the slower the shuer speed is. It ensures full exposure in
underexposure condion.
10.4.5 Focus
It oers opons to adjust the focus mode, focus range, and the minimum focus distance.
Focus Mode
Semi-auto
The device focuses once aer the PTZ and lens zooming. If the image is clear, the focus does
not change when the scene changes.
Manual
You can adjust the focus manually on the live view page.
Focus Range