5. Oponal: Click Cop
y to, and then select the access control device(s) to copy the parameters in
the page to the selected device(s).
Congure Parameters for Door/Elevator
Aer adding the access control device, you can congure its access point (door) parameters.
Steps
1. Click Access Control → Advanced Funcon → De
vice Parameter .
2. Select an access control device on the le panel, and then click to show the doors or oors
of
the selected device.
3. Select a door or oor to show its parameters on the right page.
4. E
dit the door or oor parameters.
Note
The displayed parameters may vary for dierent access control devices.
Some of the following parameters are not listed in the Basic Informaon page, click Advanced
to edit the parameters.
Name
E
dit the card reader name as desired.
Door Contact
You can set the door sensor as remaining closed or remaining open. Usually, it is remaining
closed.
Exit Buon Type
Y
ou can set the exit buon as remaining closed or remaining open. Usually, it is remaining
open.
Open
Duraon
Aer swiping the normal card and relay acon, the mer for locking the door starts working.
Extended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended access
needs s
wipes her/his card.
Door Le Open Timeout Alarm
The alarm c
an be triggered if the door has not been closed in a congured me period. If it is
set as 0, no alarm will be triggered.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.