MAINTENANCE
7-57
If acid is swallowed:
1. Drink large amounts of water or milk.
2. Then drink milk of magnesia, beaten eggs, or
vegetable oil.
3. Get medical attention immediately.
IMPORTANT: Add water to batteries in freezing
weather before you begin operating your
machine for the day, or else charge the
batteries.
IMPORTANT: If the battery is used with the electrolyte
level lower than the specified lower level,
the battery may deteriorate quickly.
IMPORTANT: Don’t refill electrolyte more than the
specified upper level. Electrolyte may
spill, damaging the painted surfaces
and/or corroding other machine parts.
NOTE: In case electrolyte is refilled more than the
specified upper level line or beyond the bottom
end of the sleeve, remove the excess electro-
lyte until the electrolyte level is down to the
bottom end of the sleeve using a pipette. After
neutralizing the removed electrolyte with so-
dium bicarbonate, flush it with plenty of water,
otherwise, consult the battery manufacturer.
M409-07-072