7-53
M4GB-01-030
M4GB-01-151
Use high quality DIESEL FUEL only (JIS K-2204) (ASTM 2-D).
Kerosene must NOT be used.
1. Park the machine on a level surface.
2. Lower the bucket to the ground.
3. Engage the park brake.
4. Run the engine at slow idle speed without load for 5 min
-
utes.
5. Stop the engine. Remove the key from the key switch.
6. Pull the front control lever lock to the LOCK position.
7. Check fuel gauge (1) of the monitor panel. Add fuel if
necessary.
8. To avoid condensation, fill the tank at the end of each
day’s operation. Take care not to spill fuel on the machine
or ground.
Fuel tank capacity
ZW180: 230 liters
ZW220: 285 liters
ZW250: 340 liters
ZW310: 382 liters
9. Install and lock fill cap (2) immediately after fueling.
1