106 N4680 2D Decoded Scan Engine User Guide
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
adjust the redundancy, scan the Code 128 Redundancy bar code below, then scan
a redundancy count between 0 and 10 on the Programming Chart. Then scan the
Save bar code. Default = 0.
GS1-128
<Default All GS1-128 Settings>
GS1-128 On/Off
GS1-128 Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 86) for additional information. Minimum and Maximum lengths
= 1-80. Minimum Default = 1, Maximum Default = 80.
Code 128 Redundancy
* On
Off
Minimum Message Length
Maximum Message Length