52 N4680 2D Decoded Scan Engine User Guide
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology bar code 
below. On the Symbology Charts on page 213, find the symbology you want to set 
as low priority. Locate the Hex value for that symbology and scan the 2 digit hex 
value from the Programming Chart (inside back cover). 
If you want to set additional low priority symbologies, scan FF, then scan the 2 digit 
hex value from the Programming Chart for the next symbology. You can program 
up to 5 low priority symbologies. Scan Save to save your selection. Default = None
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority 
symbologies, you must set the time-out period. This is the period of time the scan 
engine will search for a high priority bar code after a low priority bar code has been 
encountered. Scan the bar code below, then set the delay (from 1-3,000 millisec-
onds) by scanning digits from the inside back cover, then scanning Save. Default = 
500 ms.
Preferred Symbology Default
Scan the bar code below to set all Preferred Symbology entries to their default val-
ues.
Output Sequence Overview
Output Sequence Editor
This programming selection allows you to program the scan engine to output data 
(when scanning more than one symbol) in whatever order your application 
requires, regardless of the order in which the bar codes are scanned. Reading the 
Preferred Symbology Time-out
Preferred Symbology Default