N4680 2D Decoded Scan Engine User Guide 45
Decode Time-Out
This setting defines the overall decode time-out. It is a number in milliseconds.
Scan the Decode Time-Out bar code, then scan the time-out duration from 0-
2500 ms on the inside back cover, and Save. Default = 600 ms.
Hands Free Time-Out
The Presentation Modes are referred to as “hands free” modes. If the scanner’s
trigger is pulled when using a hands free mode, the scanner changes to manual
trigger mode. You can set the time the scanner should remain in manual trigger
mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if
there have been no further trigger pulls) the scanner reverts to the original hands
free mode.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-
300,000 milliseconds) from the inside back cover, and Save. Default = 5,000 ms.
Reread Delay
This sets the time period before the scan engine can read the same bar code a sec-
ond time. Setting a reread delay protects against accidental rereads of the same
bar code. Longer delays are effective in minimizing accidental rereads. Use shorter
delays in applications where repetitive bar code scanning is required. Reread Delay
only works when in a Presentation Mode (see page 35). Default = Medium.
Low Reading Tolerance
Decode Time-Out
Hands Free Time-Out
Short (500 ms)