Message
Source
Type ~
L-R CONV HOT
DAU 1,2 JIB-30 WSP 16, BIT 5 28/0
L-R COOL TURB HOT DAU 1,2 JIB-35 WSP 16, BIT 10 28/0
L-R COWL A/I OVHT DAU 1,2 JIB-64 WSP 18, BIT 7 28/0
L-R COWL PRESS LOW FWC JIB-17,18 28/0 ~
L-R DC POWER FAIL DAU 1,2 JIB-37 WSP 16, BIT 12
28/0
L-R FUEL LEVEL LOW DAU 1,2 JIB-11 WSP 15, BIT 2 28/0
L-RMAIN FUEL FAIL DAU 1,2 JIB-41 WSP 17, BIT O 28/0
L-R PITOT HT FAIL DAU 1,2 JIB-71 WSP 18, BIT 13
G/O
L-R WING HOT DAU 1,2 JIB-40 WSP 16, BIT 15 28/0
L-R WING TEMP LOW
FWC JIB-22,23 0/28 ~
MACH TRIM LIMIT FGC
WSP38, BIT 13
MACH TRIM
OFF FGC ASCB + DISCRETES LOGIC IN FWC
RD CMB-FLT HYD OFF DAU 1,2 JIB-53 WSP 17, BIT 12 28/0 ~
RETRIM L WING DOWN
FGC
WSP38, BIT 8
RETRIM RWING DOWN FGC
WSP38, BIT 7
SNGL RUDDER LIMIT DAU 1
JIB-54 WSP 17, BIT 13
28j0
SSEC 1-2 DISABLED DADC
WSP 17, BIT 15
STAB-FLAP FAIL
DAU 1
JIB-55 WSP 17, BIT 14 28~0
STALL BARR 1-2 FL DAU 1,2 JIB-38 WSP 16, BIT 13
0/28
STALL BARRIER OFF DAU 1
JIB-57
WSP 18, BIT O 28/0
STALL BARRIER 1-2
DAU 1,2 JIB-44 WSP 17, BIT 3
28/0
STBY PITOT HT FAIL
DAU 1
JIB-76 WSP 19, BIT 2
STEER BY WIRE FAIL
FWC JIA-26
:{: A
TAT PROBE HT FAIL DAU 2 JIB-76 WSP 19, BIT 2 G/O
TRIM LIMIT FGC WSP38, BIT 1
TRU FAIL
DAU 1
JIB-58 WSP 18, BIT 1
28j0
TRU HOT DAU 2 JIB-50 WSP 17, BIT 9 28/0
UTILITY HYD OFF
DAU 1
JIB-60 WSP 18, BIT 3
28/0
YAW DAMPER OFF FGC ASCB + DISCRETES
LOGIC IN FWC
~ Message enable state/nortnaloperation.
~ CCA certification only.
~ GEAR DOWN discrete (FWC JIA-67) must be active ground.
~ Corresponding COWL A/I discrete (DAU 1,2 JIB-18, WSP 15,
BIT 9) must be active (28 V) for at least 15 seconds.
~ Corresponding WING A/I
discrete (DAU 1,2 JIB-17, WSP 15,
BIT 8) must be active (28 V) for at least 2 minutes.
A
-905
FWC Only.
CAS Amber Caution Messages
Table 203 (cent)
22-14-00
Page 284
Apr 15/93
Use or disclosure of information on this page is subject to the restrictions on the title page of this document.