MAINTENANCE
Honeywell H!%!#h.
Omega Station Deselect (Octal Label 272)
BIT 333222222222211111 11111000000000
210987654321098765 43210987654321
P
SSM
Station manually deselected
SDI
01011101
P -
Odd Parity
SSM - 00 valid
01 invalid
SDI
- 00
all units
01 unit #1
10 unit 112
11 unit #3
Station Assignments
-
Logic 1 represents a deselect.
~ Station
12
JXN (Norway VLF)
13 GOD (Anthorne VLF)
NAU (Puerto Rico VLF)
;:
A (Norway Omega)
16
B (Liberia Omega)
17 C (Hawaii Omega)
18
D (Dakota Omega)
E (Reunion Omega)
;:
F (Argentina Omega)
21
G (Australia Omega)
22 H (JaDan Omeaa)
NWt
:: NDT
25 GBR
NAA
:! NPM
28 NSS
29 NLK
~Austral~a’VLF)
(Japan VLF)
(Great Britain VLF) I
(Maine VLF)
(Hawaii VLF)
(Annapolis VLF)
(Washington VLF)
Output Word Formats
Table 207
22-14-00