List of UI and Access configuration parameters
Config
parameter
number
Name
Type/
Unit
Range
(min-Max)
DefaultNotes
100Room Numberint0-9999 (or undefined
= 0x7FFF)
0x7FFF
101LCD Backlight
brightness
%0…100%100%
102Ring brightness%0…100%100%
103SLEEP mode ring
brightness
%0…100%100%
104Room temperature
display resolution
enum0: don't display room
temp.
1: 1 deg resolution
2: 0.5 deg resolution
3: 0.1 deg resolution
1
105Outdoor
Temperature display
resolution
enum0: 1 deg resolution
1: 0.5 deg resolution
2: 0.1 deg resolution
2
106Temperature unit &
user change option
0: °C (user can
change)
1: °F (user can
change)
2: °C (fixed)
3: °F (fixed)
0
107Cleaning Mode
Timeout
secs10-7200 seconds60 sec
108Power Button short
press function in
READY mode
enum0: No function
1: Dark Mode
2: Sleep Mode
3:SwitchLightsOnOff
Toggle
4: SwitchLightsOn
5: SwitchLightsOff
6: Hello/Goodbye
toggle
7: Hello
8: Goodbye
2Bits 3-8 not implemented yet
109Power Button long
press function in
READY mode
enumsame as above0Not implemented yet