Note 4:
OptimaandExcelfaultandwarningcodesaredisplayedintheEventHistorydataeld�
Note 5:
Subtypes Decimal Description
ECC Fault
Subtypes
1 I2CerrorreadingorwritingEEPROM
2 GALPATRAMtestfailure
4 ProgrammemoryCRCfailure
8 Opcodetestfailure
16 Can’tadjustPGAorEEPROMvaluedoesn'tmatchdigital
pot
32 Reserved
64 Reserved
128 GALPATRAMtestfailureincommonarea
mV Fault
Subtypes
1 I2CerrorreadingorwritingEEPROM
2 GALPATRAMtestfailure
4 ProgrammemoryCRCfailure
8 Opcodetestfailure
16
Can’tadjustPGAorEEPROMvaluedoesn'tmatchdigital
pot
32 RAMsafetyvariablefailure
64 Interruptsintegrityfailure
128 Stackoverow/underowfailure