XNX Universal Transmitter
Section 5 - Warnings/Faults
122
Note 4:
OptimaandExcelfaultandwarningcodesaredisplayedintheEventHistorydataeld�
Note 5:
Subtypes Decimal Description
ECC Fault
Subtypes
1 I2CerrorreadingorwritingEEPROM
2 GALPATRAMtestfailure
4 ProgrammemoryCRCfailure
8 Opcodetestfailure
16 Can’tadjustPGAorEEPROMvaluedoesn'tmatchdigital
pot
32 Reserved
64 Reserved
128 GALPATRAMtestfailureincommonarea
mV Fault
Subtypes
1 I2CerrorreadingorwritingEEPROM
2 GALPATRAMtestfailure
4 ProgrammemoryCRCfailure
8 Opcodetestfailure
16
Can’tadjustPGAorEEPROMvaluedoesn'tmatchdigital
pot
32 RAMsafetyvariablefailure
64 Interruptsintegrityfailure
128 Stackoverow/underowfailure

Table of Contents

Other manuals for Honeywell XNX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX and is the answer not in the manual?

Honeywell XNX Specifications

General IconGeneral
Ingress ProtectionIP66/67
Product TypeUniversal Transmitter
Enclosure RatingIP66/67
DisplayLCD
Communication ProtocolsHART, Modbus, Foundation Fieldbus
Power Supply24 VDC nominal, 18-32 VDC
Operating Temperature-40°C to +65°C (-40°F to +149°F)
MaterialAluminum or Stainless Steel
Gas TypesToxic, Oxygen, and Combustible gases
Output4-20 mA
Relays3 programmable relays
ApprovalsATEX, IECEx, UL, CSA
Sensor CompatibilityElectrochemical, catalytic, infrared, and other sensor types

Related product manuals