6.4.6 Accessories/Spares
Accessory/Spare Part Number Description
PipeMountKit 1226A0358
Foruseonpipesfrom2-6inches(50-150mm)indiameter�
Kitincludes:PipeMountBracket,(2)CarriageBolts,NutsandLockWashers�
RemoteECSensorMounting
Kit
S3KRMK
Theremotesensormountingkit(S3KRMK)allowstheXNXECsensorstoberemotely
mountedviaanIScablekit,upto50feet(15meters)fromthetransmitter�Thekitincludes
50feetofshieldedcable,cableglandsandremoteterminalbox�Thecablecanbecut
totherequiredlengthandterminatedattheremoteterminalbox�
CeilingMountBracketKit 1226A0355
TheoptionalCeilingMountBracketKitallowstheXNXtobemountedtotheceiling�
Kitincludes:(2)StainlessSteelCeilingMountBrackets,boltsandnuts�
1226A0382 MPD Adapter Ring
S3KDMK EC/MPD Duct Adapter Kit
DuctMountKit S3KDMK
Theductmountingkit(S3KDMK)canbeusedwiththeECsensortoallowdetectionof
O2,CO,H2andH2Sgasesinducts�
WhencombinedwiththeMPDInterfaceAdapter(1226A0382),theductmountingkitcan
accommodatetheMPDtodetectammablegasesinaductapplication�Theductmount
kitincludestheadapter,gasketand requiredfasteners�The MPD InterfaceAdapter
includesonlytheadapterandrequirestheS3KDMKductmountkit�
MPDInterfaceAdapter 1226A0382
CalibrationGasFlowAdapter
1226A0411 MPD
02000-A-1645 SensepointHT
00780-A-0035 705
CalibrationCup S3KCAL
XNXEC-Thecalibrationcupisusedtoapplycalibrationtestgastothesensor�Itpushts
ontothebottomofthesensorandcanbettedwithoutremovingtheweatherproofcover�

Table of Contents

Other manuals for Honeywell XNX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX and is the answer not in the manual?

Honeywell XNX Specifications

General IconGeneral
Ingress ProtectionIP66/67
Product TypeUniversal Transmitter
Enclosure RatingIP66/67
DisplayLCD
Communication ProtocolsHART, Modbus, Foundation Fieldbus
Power Supply24 VDC nominal, 18-32 VDC
Operating Temperature-40°C to +65°C (-40°F to +149°F)
MaterialAluminum or Stainless Steel
Gas TypesToxic, Oxygen, and Combustible gases
Output4-20 mA
Relays3 programmable relays
ApprovalsATEX, IECEx, UL, CSA
Sensor CompatibilityElectrochemical, catalytic, infrared, and other sensor types