EasyManuals Logo

Honeywell XNX Technical Manual

Honeywell XNX
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
XNX Universal Transmitter
Section 6 - Specications
131
6.2.2ECSensorPerformanceData,FactoryMutualVeried(seeSection6.3)
Gas Cartridge P/N
Selectable Full
Scale Range (Dis-
play and 4-20mA
Full Scale)
Default
Range
Range
Incre-
ments
Lower
Alarm
Limit
Lower
Detection
Limit
Lower
Explosive
Limit
(% Vol)
Zero
Deviation
Selectable
Cal Gas
Range
Default
Cal Point
Response
Time (T50)
sec
Response
Time (T90)
sec
Accuracy
Operating Temperature Operating Humidity
Min Max Min Max
O
2
Oxygen XNXXSO1FM n/a 23.0%Vol n/a 5.0%Vol 5%Vol n/a n/a
20.9%Vol
(fixed)
20.9%Vol T20<10 <30 <+/-0.5%Vol -30°C/-34°F 55°C/131°F 15%RH 90%RH
H
2
S HydrogenSulfide XNXXSH1FM 10.0to50.0ppm 15.0ppm 0.1ppm 5.0ppm 1.5ppm n/a -2.5ppm
30to70%
ofthe
selectedfull
scalerange
10ppm <20 <30
2ppmor10%of
reading,whicheveris
greater
-40°C/-40°F 55°C/131°F 15%RH 90%RH
CO CarbonMonoxide XNXXSC1FM
1
100to1000ppm 300ppm 100ppm 30ppm 15ppm na/ -25ppm 100ppm <15 <30 Seefootnote1 -40°C/-40°F 55°C/131°F 15%RH 90%RH

FOOTNOTES:
1.XNXXSC1FMaccuracyovertemperature<±10%ofreading20°C/68°Fto55°C/131°F,<±20%ofreading20°C/68°Fto-10°C/14°F,<±30%ofreading-10°C/14Fto-20°C/-4°F�
Recalibrationisrecommendedifthetemperatureofthelocalenvironmenthasvariedbymorethan-30°C�
NOTES:
• Performanceguresaremeasuredbytestunitscalibratedat50%offullscale,atambientconditionsof20°C,50%RH,withtheECweatherproofcoverattached
• IPratingofFMCartridgesisIP63�
• BarometricpressureeffectsontheO
2
sensor:TheoutputfromtheO
2
sensorhaspressureeffectsof<0�1%changeofoutputper%changeinpressure�Whenthebarometric
pressurechangesby±20%theoutputfromtheO
2
sensorchanges<±0�4%Vol�However,theoxygensensorshowstransientbehaviorwhensubjectedtoarapidchangein
ambientpressureduetoeitherweatheroraltitude�Forexample,a10KPainstantaneouspositivepressurestepchangemaycauseanoverscalealarmconditionforaperiod
ofabout12seconds�
• OperatingtheXNXECsensoratextendedtemperaturerangesforaprolongedtimeperiodexceeding12hoursmycausedeteriorationinthesensorperformanceandshorten
sensorlife�ExtendedtemperaturerangeforXNXECsensorsis-40°Cot-20°C�
• Responsetimesmayincreaseatlowertemperatures�
• FMperformanceverificationislimitedtotherequirementsofthestandardsidentifiedinTable6�3foreachcartridge�
• ContactHoneywellAnalyticsforadditionaldataordetails�

Table of Contents

Other manuals for Honeywell XNX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX and is the answer not in the manual?

Honeywell XNX Specifications

General IconGeneral
Ingress ProtectionIP66/67
Product TypeUniversal Transmitter
Enclosure RatingIP66/67
DisplayLCD
Communication ProtocolsHART, Modbus, Foundation Fieldbus
Power Supply24 VDC nominal, 18-32 VDC
Operating Temperature-40°C to +65°C (-40°F to +149°F)
MaterialAluminum or Stainless Steel
Gas TypesToxic, Oxygen, and Combustible gases
Output4-20 mA
Relays3 programmable relays
ApprovalsATEX, IECEx, UL, CSA
Sensor CompatibilityElectrochemical, catalytic, infrared, and other sensor types

Related product manuals