6.2 Sensor Data
6.2.1 Operating and Storage Conditions for Performance Tested EC Cartridges
Gas
Cartridge
P/N
Operating Pres-
sure
Operating Air
Speed
Warm-up Time
(minimum)
Storage Conditions*
Temperature Pressure Humidity Time**
O
2
Oxygen
XNXXSO1SS
80kPa~120kPa 0~6m/sec 60sec. 0to20°C,32to68°F 80to120KPa 5to95%RH 6months
XNXXSO1FM
H
2
S HydrogenSulfide
XNXXSH1SS
80kPa~120kPa 0~6m/sec 60sec. 0to20°C,32to68°F 70to110KPa 30to70%RH 6months
XNXXSH1FM
H
2
S(High) HydrogenSulfide XNXXSH2SS 80kPa~120kPa 0~6m/sec 60sec. 0to20°C,32to68°F 70to110KPa 30to70%RH 6months
CO CarbonMonoxide
XNXXSC1SS
80kPa~120kPa 0~6m/sec 60sec. 0to20°C,32to68°F 70to110KPa 30to70%RH 6months
XNXXSC1FM
*Storeinsealedpackages**Checkcartridgecertificates