Section 6 - Specications
145
XNX Certications by XNX-AM Series
XNX Part Number Series
XNX Transmitter
IR Personality
XNX Transmitter mV Personality XNX Transmitter EC Personality
Options
XNX-AMSI-*****
XNX-AMAI-*****
XNX-AMSV-***** / XNX-AMAV-***** XNX-AMSE-***** / XNX-AMAE-*****
With Generic 20 mA Input
With Optima Plus
With Searchline Excel
MPD-AMCB1 (Cat Bead)
MPD-AMIV1 (IR Methane)
MPD-AMIF1 (IR Flam)
MPD-AMIC1 (IR CO
2
)
With 705 HT
With Sensepoint
With Sensepoint PPM
With Sensepoint HT
With Oxygen Cartrdige
With H
2
S Low Cartridge
With H
2
S Med Cartridge
With H
2
S High Cartridge
With CO Cartridge
SO
2
, NH
3
, Cl
2
, ClO
2
, NO, NO
2
,
H
2
PPM HCL, HCN, HF, O
3
, PH
3
Modbus
Relays
Local HART
Foundation Fieldbus
Electromagnetic &
Safety;
CE Mark
EMC Compliance
EU directive 2004/108/EC
M M M M M M M M M M M M M M M M M M M M M
EN 50270:2006
B B B B B B B B B B B B B B B B B B B B B
EU directive 94/9/EC
M M M M M M M M M M M M M M M M M M M M M
Hazardous Location
---
ATEX/DEMKO
IECEx
EN 60079-29-0: 2009
M M M M M M M N/A M M M M M M M M M M M M M
EN 60079-29-1: 2007
M M M M M M M N/A M M M M M M M M M M M M M
EN 60079-11: 2012
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M M M M M M N/A N/A M N/A
EN 60079-26: 2007
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M M M M M M N/A N/A N/A N/A
IEC 60079-31 1st Ed
M M M M M M M N/A N/A N/A M M M M M M M M M M M
IEC 60079-0 6th Ed
M M M M M M M N/A M M M M M M M M M M M M M
IEC 60079-1 6th Ed
M M M M M M M N/A M M M M M M M M M M M M M
IEC 60079-11 6th Ed
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M M M M M M N/A N/A M M
IEC 60079-26 2nd Ed
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A M
1
M
1
M
1
M
1
M
1
M
1
N/A N/A N/A N/A
EN 60079-31: 2009
M M M M M M M N/A N/A N/A M M M M M M M M M M M
B=Both3/4NPTandM25
M=M25threadedTransmitters&Adapters
M
1
=WhenusedwithS3KRMKinaZone0location
N/A=NotApplicable

Table of Contents

Other manuals for Honeywell XNX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX and is the answer not in the manual?

Honeywell XNX Specifications

General IconGeneral
Ingress ProtectionIP66/67
Product TypeUniversal Transmitter
Enclosure RatingIP66/67
DisplayLCD
Communication ProtocolsHART, Modbus, Foundation Fieldbus
Power Supply24 VDC nominal, 18-32 VDC
Operating Temperature-40°C to +65°C (-40°F to +149°F)
MaterialAluminum or Stainless Steel
Gas TypesToxic, Oxygen, and Combustible gases
Output4-20 mA
Relays3 programmable relays
ApprovalsATEX, IECEx, UL, CSA
Sensor CompatibilityElectrochemical, catalytic, infrared, and other sensor types