SP-PPM (10% LEL)
Hydrogen Methane-1 Methane-2
Lower Alarm
Limit (% LEL)
2.0 2.0 2.0
Upper Alarm
Limit (% LEL)
10 10 10
% Volume
Reference
4.0 5.0 4.4
SP-PPM
Hydrogen Methane
Lower Alarm
Limit (% LEL)
1000 ppm 1000 ppm
Upper Alarm
Limit (% LEL)
5000 ppm 5000 ppm
% Volume
Reference
n/a n/a
SP-HT-NH3
Ammonia
Lower Alarm
Limit (% LEL)
3000 ppm
Upper Alarm
Limit (% LEL)
30000 ppm
% Volume
Reference
n/a

Table of Contents

Other manuals for Honeywell XNX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX and is the answer not in the manual?

Honeywell XNX Specifications

General IconGeneral
Ingress ProtectionIP66/67
Product TypeUniversal Transmitter
Enclosure RatingIP66/67
DisplayLCD
Communication ProtocolsHART, Modbus, Foundation Fieldbus
Power Supply24 VDC nominal, 18-32 VDC
Operating Temperature-40°C to +65°C (-40°F to +149°F)
MaterialAluminum or Stainless Steel
Gas TypesToxic, Oxygen, and Combustible gases
Output4-20 mA
Relays3 programmable relays
ApprovalsATEX, IECEx, UL, CSA
Sensor CompatibilityElectrochemical, catalytic, infrared, and other sensor types