Chapter 3
Preparing Superdome for Booting
Connecting the CE Tool to the A500 Support Management Station
67
Connecting the CE Tool to the A500 Support Management Station
NOTE The information in the following sections applies to the A500 Support Management Station
(SMS) only.
Connecting the CE Tool to the SMS allows you to configure the SMS. It requires a 9-pin female to 25-pin male
serial cable:
Step 1. Disconnect the serial cable from the Local RS-232 port on the GSP and the CE tool.
Step 2. Connect one end of the serial cable (9-pin female to 25-pin male, P/N 24542G) to the serial port on
the CE tool.
In Figure 3-29, this connection is shown as a dotted line between the CE TOOL (PC) and the SMS.
Figure 3-29Superdome LAN Interconnect Diagram
Step 3. Connect the other end of the serial cable to the port on the SMS labeled Console UPS Port.
PC/Workstation
Console Access
NOTE:
Preferred method
of GSP access
CE Tool (PC)
For initial install of SMS,
serial cable 24542G needed.
Customer Site LAN
(if desired)
Modem
Private LAN Port
Customer LAN Port
RS232 Local
RS232 Remote
Guardian Service
Processor (GSP)
*LAN Hub
0000
LAN Console
Port
10/100 Base-T Port
Support Management
Station
High Availability Observatory
or other info structure to
remotely connect to the
HP Service Location or
customer site LAN.