Enabling bi-directional CHAP during discovery session and bi-directional CHAP
during normal session
Table 12 lists the settings you use to enable bi-directional CHAP during a discovery session and
bi-directional CHAP during a normal session.
Table 12 CHAP bi-directional settings
Microsoft initiator secret settingsMPX200 secret settings
Setting (example)ActionSetting (example)Source
hpstorageworks
General Tab Secret
hpstorageworks
iSCSI Port
CHAPsecret0
Add Target Portal
CHAPsecret01
Discovered iSCSI
initiator
CHAPsecret01
Log on to Target
hpstorageworks
iSCSI Presented
Target
NOTE:
These are examples of secret settings. Configure CHAP using settings that apply to your network
environment.
1. Enable CHAP for the MPX200 discovered iSCSI initiator entry (CHAP can be enabled via CLI
only):
a. If the iSCSI initiator is not listed when you execute the set chap command, do one of the
following:
From HP Command View EVA, select Hosts and then select the Add Host tab. Enter the
IQN name string.
From the CLI, enter the initiator add command and add the iSCSI initiator that will
perform the discovery.
b. If the iSCSI initiator is listed under the set chap command, enable CHAP secret (for
example: CHAPsecret01).
a. Select the index of the iSCSI initiator.
b. To Enable CHAP, select 0, then enter the CHAP secret.
2. Enable CHAP for the MPX200 iSCSI port:
a. To enable CHAP for the MPX200 iSCSI port using HP Command View:
Select the appropriate iSCSI Controller, then select the IP Ports tab, and then select the
appropriate IP Port.
Under Security, select Enabled in CHAP Status, and then enter the CHAP Secret (for ex-
ample: hpstorageworks).
Select the Save Changes tab to save the changes.
b. Enable CHAP for the MPX200 iSCSI port using the MPX200 CLI:
Enter the set chap command.
Select the appropriate Portal iqn name index that the initiator will log in to.
Select 0 to enable CHAP.
Enter a CHAP secret (for example: hpstorageworks).
MPX200 iSCSI configuration rules and guidelines98

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6100 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6100 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6100 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals