Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error contentError code (SSB2)Error code (SSB1)
Cnt Ac-J pair status cannot be transited during the power-off processing.DB08
A request of Cnt Ac-J Pairresync (journal resync mode) was rejected because
the specification was volume instead of group.
DB0C
A request of Cnt Ac-J Paircreate was rejected because the CLPR number of
the specified volume differed from the CLPR number of the journal.
E843
A request of Cnt Ac-J Paircreate was rejected because the specified volume
belongs to the journal that is contained in the Cnt Ac-J-Continuous Access
Synchronous combination (2DC) configuration in the intermediate site.
E846
An operation request for the journal, which was used in the system that
consists of single primary and secondary system, was rejected because the
specified volume is defined to be used in the system that consists of multiple
primary and secondary systems.
E847
An operation request for the journal, which was used in the system that
consists of multiple primary and secondary systems, was rejected because
the specified volume is defined to be used in the system that consists of
single primary and secondary system.
E848
The specified consistency group number is already used.E866
A request of Cnt Ac-J Paircreate was rejected because the path between
the storage devices for the both-way was not defined. Check whether the
bidirectional normal path was defined or not.
E871
A request of Cnt Ac-J Paircreate was received. However, the pair could not
be created because the serial number of secondary system which was
specified was incorrect.
E876
A request of Cnt Ac-J Paircreate was rejected because the specified volume
was different from the LDKC of the specified journal. A pair in the same
journal cannot be set across two LDKCs.
E879
Troubleshooting using RAID Manager 115