EasyManua.ls Logo

HP StoreFabric SN6500B

HP StoreFabric SN6500B
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
418 Fabric OS Administrator’s Guide
53-1002745-02
Working with EX_Ports
14
EX_Port commands
See the Fabric OS Command Reference for more details on these EX_Port -valid commands.
portCfgExPort
The portCfgExPort command sets a port to be an EX_Port, and also sets and displays EX_Port
configuration parameters (including those for encryption and compression).
Usage: portCfgExPort <action> [slot/]port
Example Setting port 47 to be an EX_Port, and displaying the port configuration parameters
switch:admin> portcfgexport 47
Port 47 info
Admin: enabled
State: OK
Pid format: core(N)
Operate mode: Brocade Native
Edge Fabric ID: 17
Preferred Domain ID: 160
Front WWN: 50:00:53:31:37:03:ee:11
Principal Switch: 8
Principal WWN: 10:00:00:05:33:13:70:3e
Fabric Parameters: Auto Negotiate
R_A_TOV: 10000(N)
E_D_TOV: 2000(N)
Authentication Type: DHCAP
DH Group: 4
Hash Algorithm: SHA1
Encryption: ON
Compression: ON
Forward error correction: ON
Edge fabric's primary wwn: N/A
Edge fabric's version stamp: N/A
fcrEdgeShow
The fcrEdgeShow command displays the encryption and compression status for a switch.
Usage: fcrEdgeShow
Example Displaying the port configuration parameters for a switch
switch:admin> fcrEdgeShow
FID EX-port E-port Neighbor Switch (PWWN, SWWN) Flags
------------------------------------------------------------------------------
34 4/12 9 20:09:00:05:33:7e:e8:7c 10:00:00:05:33:7e:e8:7c ENCRYPTI
ON COMPRESSION
34 4/13 10 20:0a:00:05:33:7e:e8:7c 10:00:00:05:33:7e:e8:7c ENCRYPTI
ON COMPRESSION
EX_Port downgrade considerations
Firmware downgrading is blocked if one or more EX_Ports has the Encryption/Compression feature
enabled.