Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual -169-
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F18.10
Set the display
parameter 3 at stop
frequency
32: Heatsink temperature
33: Set the line speed
34: Reference line speed
35-36: Reserved
37: Process PID reference
38: Process PID feedback
39: Process PID error
40: Process PID integral
value
41: Process PID output
42: External couting value
43: Input terminal status
44: Output terminal status
45: MODBUS
communication status
46: Actual length
47: Total length
48: Total time at power on
(hour)
49: Total time at running
(hour)
20 1 ○
F18.11
Set the display
parameter 4 at stop
22 1 ○
F18.12
Set the display
parameter 5 at stop
43 1 ○
F18.13
Set the display
parameter 6 at stop
44 1 ○
F18.14
Reserved
F18.15
Maximum line speed
0-65535 1000 1 ○
F18.16
Line speed display
accuracy
0: Integer
1: One decimal
2: Two decimal
3: Three decimal
0 1 ×
Group F19 Function-boost Parameters (refer to pages 109
116)
F19.00
Auxiliary frequency
setting source
selection
0: No auxiliary source
1: Digital setting 1 (the initial
value is set by F19.03 and
adjusted by and
keys on the display panel)
2: Digital setting 2 (the initial
value is set by F19.03 and
adjusted by terminals
UP/DN)
3: Digital setting 3 (the initial
value = 0, set by SCI direct
communication
4: AI analogue setting
5: Terminal pulse setting
6: Process PID output
0 1 ○
A