Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd
―170― HD30 Series Inverters User Manual
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F19.01
Master/Auxiliary setting
calculation
0: Master setting + auxiliary
setting
1: Master setting – auxiliary
setting
2: MAX (master setting,
auxiliary setting)
3: MIN (master setting,
auxiliary setting)
4: Master setting + auxiliary
setting × master setting /
max. value of master setting
5: Master setting – auxiliary
setting × master setting /
max. value of master setting
0 1 ○
F19.02
Analogue auxiliary
setting coefficient
0.00-9.99 1.00 0.01 ○
F19.03
Initial value of digital
auxiliary frequency
0.00-F00.06 0.00Hz 0.01Hz ○
F19.04
Control selection of
digital auxiliary
frequency
Units: Save selection at
power outage (Only when
F19.00 = 1 or 2 will F19.04
be enabled)
0: Not save auxiliary
frequency at power outage
1: The auxiliary frequency
will be saved to F19.03 at
power outage
Tens: Frequency disposal
when the inverter stops (Only
when F19.00 = 1 or 2 will
F19.04 be enabled)
0: Maintain the auxiliary
frequency when the inverter
stops
1: The auxiliary frequency
clears to zero when the
inverter stops
00 1 ○
F19.05
Adjustment selection of
setting frequency
0: No adjustment
1: To adjust as per the max.
output frequency
2: To adjust as per the
current frequency
1 1 ○
F19.06
Adjustment coefficient
of setting frequency
0.0-200.0% 100.0% 0.1% ○
F19.07
Control selection of
cooling fan
0: Auto stop mode
1: Immediate stop mode
2: The fan runs continuously
0 1 ○