Appendix A Parameter
66 MONT20 User Manual V1.6
ef. Code
Function Setting Range Default Attribute
Setting
F06.12 Auxiliary parameter 1
Hundred: CD limit switching mode
0: Do not learn the CD limit position during
door width self-learning
1: Learn the CD limit potision during door
width self-learning
Ten: Demo mode enable
0: Enable manually
1: Enable automatically
Unit: OD/CD priority selection
0: OD priority
1: CD priority
00000
○
F06.13 Auxiliary parameter 2
Ten thousand: Abnormal shutdown
protection is opened
0: Open
1: Not open
Thousand: Current slope rise
0: Start current direct sets
1: Start current slope rise
Hundred: Speed loop amplification
0: KP is original value
1: KP amplify by 4 times
Ten: Over-current auto reset enable
Unit: Over-vlotage auto reset enable
0: Not enable
1: Enable
00001
○
F06.14
On board LCD brightness
adjustment
0 - 100% 70%
○
F06.15 Carrier frequency 4 - 16k 8k
×
F06.16
Running speed when prising
door for Asyn. motor open-
loop
2.50 - 15.00Hz 4.00Hz
○
F06.17 CD time protection 0 - 30s 0s
○
F06.18
Flux vector voltage
compensation
0 - 40% 10%
×