Figure B-2 Preparing an OT terminal
(1) Cable (2) OT terminal (3) Heat shrink tubing
(4) Hydraulic pliers (5) Heat gun
B.3 Preparing a PV Input Power Cable
CA UTION
Use the delivered Staubli MC4 EVO2 positive and negative metal terminals and
connectors. Using incompatible positive and negative metal terminals and
connectors may result in serious consequences. The caused device damage is
not covered under any warranty or service agreement.
Use professional tools to prepare cables.
NO TICE
Cables with high rigidity, such as armored cables, are not recommended.
Before assembling connectors, label the cable polarities correctly to ensure
correct cable connections.
A PV-CZM-41100 crimping tool is recommended.
Use the wrench shown in the
gure to tighten the locking nut. When the
wrench slips during the tightening, it indicates that the locking nut has been
tightened.
After crimping the positive and negative metal terminals, pull the PV input
power cables to ensure that they are connected securely.
Insert the crimped metal terminals of the positive and negative power cables
into the appropriate positive and negative connectors. Then pull the PV input
power cables to ensure that they are connected securely.
iSitePower-M V100R002C00 User Manual
(MAP05A1, MAB05B1)
iSitePower-M V100R002C00 User Manual
(MAP05A1, MAB05B1) B Preparing the Cable and Terminal
Issue 01 (2022-07-15) Copyright © Huawei Technologies Co., Ltd. 186