GSP9700 Series Road Force Measurement System Operation 5. Balancing Features and Options 97
From the “Details” popup screen, “Show Runout Plots” may be selected. From this
screen, a graphic depiction of the measured data, multiple harmonics, road force,
and runout may be viewed. Refer to “Harmonics & T.I.R. Data/Plots,” page 98.
5.15 Print Summary
Balance and road force screens have “Print Summary” and “Save ‘Before’
Measurements” keys on the last key row. The printout combines data from the
balance, road force, and diagnosis explanation (if it exists) screens, replacing up to
four screen prints with one much faster formatted output.
Press the “Save ‘Before’ Measurements” key to save the balance, road force, and
runout measurements for later printing along with measurements after balancing and
ForceMatching.
NOTE: “Before” measurements are retained only as long as power
is left on.
Imbalance condition, static vs. dynamic, and balance weight types are printed. Split
and Spoke weight values are printed as the single weight equivalent (better indication
of imbalance since weight angles are not printed).
The diagnosis box is printed along with assembly first harmonic result and the road
force selector switch setting (P/SUV/LT). If non-first harmonic failures occur (the
“Diagnosis Explanation” screen level exists), a second page is printed to show that
data.
Tire road force and rim runout are not printed on the main printout page. If this
information is desired, printing while in service mode will produce an additional page
duplicating the charted information on the “Show Details” screen through fourth
harmonics.
Print Summary While Matching Prediction Is Displayed:
If you have the road force screen set to “Show After ForceMatching” and then do a
print summary, “Print Current” will print both the current and the predicted information
on one page. Printing “Before and Current Measurements” together is not allowed in
this case.