GSP9700 Series Road Force Measurement System Operation 4. Balancing a Wheel 43
With the servo enabled, attach the adhesive weight using the weight amount shown
for the right weight plane on the CRT. Refer to “Servo-Aided Adhesive Weight
Placement,” page 51. If servo is not enabled, BDC placement should be used. Refer
to “Manual Weight Position Measurement,” page 48.
SERVO
-
AIDED
ARM CONTACT POINT
BDC
If necessary, use the right “ ” to split the weight. Refer to “Split Weight
®
Feature,” page 87.
Verify balance condition by spinning again with the load roller disabled. Refer to
“Load Roller Operation,” page 60.
Left and right weight plane displays should show “zero.”
MIXED WEIGHTS balancing procedure is complete.
ADHESIVE WEIGHTS Balancing Procedure (Adhesive Weights Only)
Verify that the wheel is clean and free of debris.
Remove all previous weights.
Mount tire/wheel assembly. Refer to “Mount the Wheel on the Spindle Shaft,” page
23.
Press “
.”
Use the arrows to select “ADHESIVE WEIGHTS BALANCE” and press “OK.”
Select either grams or ounces by rotating the control knob and highlighting either “g”
or “oz.”
Select “DYNAMIC” by rotating the control knob to highlight “
.” Refer to “Dynamic
Balancing Selection,” page 37.