44 4. Balancing a Wheel GSP9700 Series Road Force Measurement System Operation
Using the DOWNWARD position, place the inner Dataset
®
arm disk edge to the
outermost location for placement of the right edge of the left adhesive weight and
enter the data by depressing the foot pedal. Refer to “Using the Auto Dataset
®
Arms,”
page 48.
Do NOT return the inner Dataset
®
arm to the “home” position.
Using the DOWNWARD position, move the inner Dataset
®
arm disk edge to the
innermost location for placement of the right edge of the right adhesive weight and
enter the data by depressing the foot pedal. Refer to “Using the Auto Dataset
®
Arms,”
page 48.
Close safety hood.
Press the green “START” button if “Hood Autostart” is disabled.
After wheel comes to a complete stop, raise the safety hood.
With the servo enabled, attach the adhesive weight for the left weight plane using the
weight amount shown on the CRT. Refer to “Servo-Aided Adhesive Weight
Placement,” page 51. If servo is not enabled, BDC placement should be used. Refer
to “Manual Weight Position Measurement,” page 48.
SERVO-AIDED
ARM CONTACT POINT
BDC
If necessary, use the left “ ” to split the weight. Refer to “Split Weight
®
Feature,” page 87.
Return the inner Dataset
®
arm to the home position.