104  6. Equipment Information  GSP9700 Series Road Force Measurement System Operation   
Remove the installed program cartridge from the CRT support console. 
Insert the new program cartridge into the console. Ensure proper alignment of the 
cartridge guides with the console alignment guides. Press the cartridge into the data 
communications board receptacle.  
Reinstall the access panel and secure with the two Phillips screws previously 
removed. 
Re-attach the AC power cord, turn the unit “ON” and verify operation. 
AFTER INSTALLING PROGRAM CARTRIDGE: 
View setup options by selecting “Setup” from the “Balance” primary screen. Change 
setup options to the desired settings. Press “Store Setup” to complete “Setup” 
procedures. 
NOTE:  The GSP9700 may request to be completely 
re-calibrated after program cartridge installation. Refer 
to “Calibration Procedures,” page 116. Calibration tool,  
221-602-1, is required. 
6.3 Balancer Set Up  
The “Set Up” primary screen contains a list box of set up items and may be selected 
from the second row of softkeys on the “Logo” primary screen. As the set up features 
are individually highlighted by selecting “” or “”, the equipment components for 
each set up procedure are shown in yellow on the illustrated GSP9700. 
 
Change set up features by selecting “Set Up Selected Item.” The gray box at the top 
of the item set up menu displays the current setting for each feature. The blue box in 
the middle of the set up screen describes the highlighted choice from the list box 
below. Use the soft keys to select the desired setting for each feature. Select “OK” 
when the desired choice is highlighted. To exit set up procedures and save changes 
that were made, select  “Store Set Up” from the menu. The screen will automatically 
return to the “Logo” screen. 
NOTE:  The set up information is not stored until “Store Set Up” is 
pressed on the wheel balancer “Set Up” screen. 
To abandon the set up procedures without saving changes, select the “Cancel” key 
or simply reset the system.