128 7. Calibration and Maintenance GSP9700 Series Road Force Measurement System Operation
Changing Ribbon Cartridge (P/N 162-42-2):
Remove the access cover by lifting it off.
Slide the printhead to the middle of the printer away from the rollers on the bail.
Grasp the cartridge on both sides and lift up.
Snap the new cartridge on the printhead plate. (Tilt the back of the cartridge so it
slides into the plate, lower the top of the cartridge over the printhead aligning the tabs
on either side with the inserts on the printhead plate.)
Reinstall the access cover.
Bottom Feed Paper Loading
Turn the printer “OFF.”
Remove printer paper from packaging and place into recess in printer drawer.
Feed paper through bottom of printer and place printer into drawer.
Remove the access cover and lift the bail.
Open the paper lever.
Insert first sheet of paper through the paper separator and into the paper guides.
Continue to slide paper until it appears in front of the roller.
Align the holes of the paper with the corresponding pins of the adjustable pin feeds.
Lower the bail.
Use the roller knob to advance the paper to the first printing line location.
Replace the access cover and turn the printer on.
NOTE: After changing the ribbon cartridge, loading paper, or
clearing a jam, turn the printer “OFF” and then back “ON.”
7.4 Cleaning the Console
When cleaning the console, use window cleaning solution to wipe off the display
console and cabinet. Do not spray window cleaning solution directly onto control
panel or CRT. Power should be “OFF” prior to cleaning the CRT.
WARNING: Exposing the balancer to water either by hose, bucket,
or weather may cause risk of electrical shock to
operator or bystanders and will damage the electrical
system. Place, store, and operate the balancer only in a
dry, sheltered location.