116  7. Calibration and Maintenance  GSP9700 Series Road Force Measurement System Operation   
7. Calibration and Maintenance 
7.1 Calibration Procedures 
The “Calibration” primary screen can be selected by pressing “Calibrate” from the 
“Logo” screen. The “Calibration Procedures” primary screen contains a list box of 
calibration procedures. As the procedures are individually highlighted by selecting  
“” or “”, the equipment components to be calibrated for each procedure are shown 
in yellow on the illustrated GSP9700. 
Begin calibration procedures by selecting “Begin Procedure.” When finished 
calibrating, select “Exit.”  
Throughout the calibration procedures, “Back Up” can be selected to return to the 
previous step. 
The calibration weight used for calibrating the balancer and the inner dataset arm is 
stored in one of the weld nuts located on the back of the base assembly or in the 
weight tray. 
 
 
BACK OF 
BALANCER 
CALIBRATION 
WEIGHT 
WELD NUT 
 
Dataset
®
 arm and load roller calibrations require the optional calibration tool,  
221-672-1.