GSP9700 Series Road Force Measurement System Operation 7. Calibration and Maintenance 123
Place the outer Dataset
®
arm ball in the hole for position “4.” Tap the foot pedal once
or press “Enter Cal Step.”
Place the outer Dataset
®
arm at position “5.” Tap the foot pedal once or press “Enter
Cal Step.”
Place the outer Dataset
®
arm at position “6.” Tap the foot pedal once or press “Enter
Cal Step.”
Rotate the outer arm ball back to the upward position.
Outer Dataset
®
arm calibration is complete.
Load Roller (Calibration Tool, 221-672-1, Required)
Select “Calibrate” from the “Logo” screen.
Select “Load Roller” from the “Calibration Procedures” primary screen.
Select “Begin Procedure.”
Verify that the load roller is in the “home” position and is not moving. Tap the foot
pedal once or press “Enter Cal Step.”
Disconnect the air supply and load roller return spring.
CAUTION: Failure to disconnect the air supply may result in personal
injury.