122 7. Calibration and Maintenance GSP9700 Series Road Force Measurement System Operation
Place the outer Dataset
®
arm at position “1.” Tap the foot pedal once or press “Enter
Cal Step.”
NOTE: If the outer Dataset
®
arm is unstable while entering any step,
a long, high-pitched tone will sound to advise that the step
has NOT been entered. Stabilize the arm and re-enter the
step.
Place the outer Dataset
®
arm at position “2.” Tap the foot pedal once or press “Enter
Cal Step.”
Place the outer Dataset
®
arm at position “3.” Tap the foot pedal once or press “Enter
Cal Step.”
Loosen the outer Dataset
®
arm locking screw by turning it counterclockwise and
rotate the outer arm ball into the downward position by pulling the locator pin out of
the locator slot and rotating the ball 180 degrees. Secure the locking screw.
Place the calibration tool on the hub using the hub mounting slot as shown.