MERCHANDISER SETTINGS (Cont'd)
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 • Printed in USA
CONTROL SETTINGS Revised March 1, 1997
8 - 10
Models
Refrigeration
D i s c h a rge Air
Te m p e r a t u r e˚ F
Evaporator
Temperature˚F
Fan Cycling
CI/CO ˚F
Defrost
Frequency, Hrs
Electric
Temp Te r m ˚ F
Failsafe Min
Reverse Air
Temp Te r m ˚ F
Failsafe Min
K o o l g a s
Duration Min
O ff t i m e
Temp Te r m ˚ F
Duration Min
P4E
31°F
24°F
—
6 Hrs
—
—
—
48°F
30 Min
PW
(End)
32˚ F
21˚ F
—
8 Hrs
—
—
—
—
45 Min
P4
29°F
21°F
—
6 Hrs
—
—
—
48°F
30 Min
PW
34˚ F
21˚ F
—
8 Hrs
—
—
—
—
45 Min
PWE
34˚ F
24˚ F
—
8 Hrs
—
—
—
—
45 Min
PWE
(End)
32˚ F
24˚ F
—
8 Hrs
—
—
—
—
45 Min
Application PRODUCE