Electrical System: 9-2
TROUBLESHOOTING
1.0. CDS will not turn on
Possible Cause Solution
1.1. The main power fuse
has blown.
Remove CDS cowling and engine cover and check all
wiring from the power source back to the CDS console
for damage. Replace fuse only after locating the problem
that caused the fuse to blow. If unable to locate problem,
refer to qualied service technician.
1.2. The plug-in connection
at the base of the recovery
tank is corroded.
Clean and seal connection to protect it from moisture.
1.3. The main circuit breaker
has blown on the CDS dash.
Reset breaker and look for loose connections or damaged
wires. Check all wires from the control panel forward to
the front of the vehicle. If no problem is found but the
breaker still trips refer to qualied service technician.
2.0. CDS shuts o󰀨 while in use
Possible Cause Solution
2.1. Recovery tank is full. Empty tank and restart machine.
2.2. Recovery tank oat
switch is dirty or defective.
Inspect oat to see if the triangle mark on the oat is
facing up. If it is, and the oat slides freely on the post,
replace the oat assembly.
2.3. The vehicle gear selector
has moved.
Inspect the gear selector to be sure it is in the proper
position. If selector has moved, refer to qualied service
technician.
If vehicle gear selector has moved, refer to qualied service technician - it needs
to be repaired immediately. This is a dangerous condition and can cause death
or injury.