Operating Instructions: 3-4
10. Drain the recovery tank.
If your CDS is equipped with an AWDS, rst connect a garden hose to the outlet
on the front of the machine.
If your CDS is equipped without an AWDS, drain the recovery tank through the
tank drain valve (under the chemical jug tray).
Do not dump waste in any area which might violate local, state or federal
law. If you have the optional AWDS, drain the recovery tank into a sanitary drain
system.
11. When the recovery tank is drained, lift the recovery tank lid and remove the lter
basket.
12. Clean out any accumulated debris.
13. Rinse and re-install.
14. Check the corrugated blower lter.
15. Clean out any accumulated debris.
16. Rinse and re-install.
When re-installing the blower lter, ensure that it is fully seated against its mount
so that debris cannot pass under it and into the blower.