Water and Chemical System: 5-4
3.0. Chemical jug lls with water
POSSIBLE CAUSE SOLUTION
3.1. Three-way chemical
valve is defective.
Inspect valve for leaks between ports. Replace as
necessary.
3.2. Inlet check valve in
chemical pump is faulty.
Remove and inspect valve. Clean or replace as
necessary.
4.0. Chemical in water box
POSSIBLE CAUSE SOLUTION
4.1. Chemical pump
diaphragm is faulty.
Remove and inspect. Replace as necessary.
4.2. High-pressure check
valve is faulty.
Remove and inspect. Clean or replace as necessary.