Page #144 background image
TroubleshooTing and sysTem TesTs
5-18 powermax
65/85
Service Manual
WORK
LEAD
J13
J2
J1
J18J19
J27
J30
J23
J24
TP13
J29
TP11
TP12
380/400 V CE power supply overview
Power switch (S1)
Power board
Flyback circuit
Control board
Digital signal processor
(DSP) board
Test points
Ground
Gate drive
connectors
3uF Capacitor
MOV sub-
assembly
PFC inductor wires
Transformer
wires
Nozzle
wire
Electrode
wire
Output
inductor wire

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
Gas SupplyClean, dry, oil-free air or nitrogen
Cooling MethodFan-cooled
Input Voltage200-600V, 3-phase
Current Output25-85 A
Duty Cycle60% @ 85 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Cutting Capacity (Recommended)1" (25 mm)
Gas TypeAir/Nitrogen