TORCH SETUP
powermax
65/85
Service Manual 3-39
FineCut Air flow rate - slpm/scfh
Mild Steel
Hot 155 / 330
Cold 215 / 460
Metric
Material
Thickness
Amps
Torch-
to-Work
Distance
Initial Pierce Height
Pierce Delay
Time
Best Quality Settings
Cut Speed Voltage
mm A mm mm % seconds (mm/min) Volts
0.5
40
1.5 3.8 250
0.0
8250 78
0.6 8250 78
0.8 0.1 8250 78
1
45
0.2 8250 78
1.5
0.4
6400 78
2 5250 82
3 0.5 2750 83
4 0.6 1900 84
English
Material
Thickness
Amps
Torch-
to-Work
Distance
Initial Pierce Height
Pierce Delay
Time
Best Quality Settings
Cut Speed Voltage
A in in % seconds ipm Volts
26GA
40
0.06 0.15 250
0.0
325 78
24GA 325 78
22GA
0.1
325 78
20GA 325 78
18GA
45
0.2 325 78
16GA
0.4
250 78
14GA 220 82
12GA
0.5
120 83
10GA 95 84