Loading...
Troubleshoot Common Problems
6
102 811470 Operator Manual Powermax45 SYNC
None
Flashes
one after
the other
On
Yellow
The plasma power supply
was receiving a signal to
start cutting at the same
time that the power switch
was set to ON (I).
This fault code stops the system from operating.
Do the following.
The torch trigger was being held in the “fire”
position when the power switch on the
plasma power supply was set to ON (I).
Release the trigger and do a quick restart of
the plasma power supply. Refer to page 90.
None
On
Flashes
Yellow
An AC input voltage phase
loss occurred.
This is applicable only to
3-phase models.
This fault code stops the system from operating.
Have an electrical technician examine all
input phases and fuses/breakers for correct
voltage at the power source and at the
plasma power supply.
If applicable, disconnect the system from
generator power.
Do a cold restart. Refer to page 90.
Fault
code
Fault
LEDs
Torch
LEDs Description Solutions

Table of Contents