Complete Regular Maintenance Tasks
7
Powermax45 SYNC Operator Manual 811470 11 9
Examine the air filter bowl and filter element
It is extremely important to keep a clean, dry gas line to do the following:
Prevent oil, water, dirt, and other contaminants from causing damage to internal
components.
Get the best possible cut quality and consumable life.
Drain water from the bowl (if necessary)
A small amount of water can collect in the bottom of
the filter bowl. The filter bowl automatically removes
the water when enough water collects to engage
the float mechanism inside the bowl.
To manually drain water from the bowl, remove the
nut at the bottom of the bowl with your hand.
To prevent damage to the plastic nut, do not use a
wrench or other tool.
Remove the air filter bowl and filter element
1. Set the power switch on the plasma power supply to OFF (O).
2. Disconnect the power cord from the electrical
power.
3. Disconnect the gas supply from the rear of the
plasma power supply.
4. Remove the air filter bowl by unscrewing the metal
guard until it disconnects from the air filter
assembly inside the plasma power supply.
5. Remove the air filter bowl from the metal guard.
6. Gently pry the filter element out of the filter
bowl. Be careful not to damage the O-ring at
the top of the bowl.
Unscrew nut to remove
1
2
3
4
1
2 3
4

Table of Contents