Install and Set Up the Plasma Power Supply
2
Powermax45 SYNC Operator Manual 811470 19
What to do if components are missing or damaged
Claims for damage during shipment
Send a claim to the carrier if your system was damaged during shipment.
Get the system’s model number and serial number from the data plate on the bottom of
the plasma power supply. Refer to page 21 for a sample data plate.
Get a copy of the bill of lading from Hypertherm. For additional assistance, contact the
nearest Hypertherm office listed in the front of this manual.
Claims for missing or damaged merchandise
Speak to your Hypertherm distributor or authorized repair facility, or speak to the nearest
Hypertherm office shown in the front of this manual.
Hypertherm plasma power supply ratings
Rated open-circuit voltage (U
0
) 200 V 240 V, CSA/CE/CCC
400 V, CE/CCC
480 V, CSA
275 VDC
265 VDC
275 VDC
Output characteristic* Drooping
Rated output current (I
2
) 20 A 45 A
Rated output voltage (U
2
) 155 VDC
Duty cycle at 40°C (104°F)
**
50% at 45 A (I
2
) / 155 VDC (U
2
)
60% at 41 A (I
2
) / 155 VDC (U
2
)
100% at 32 A (I
2
) / 155 VDC (U
2
)
Operating temperature -10°C 40°C (14°F 104°F)
Storage temperature -25°C 55°C (-13°F 131°F)
Power factor 200 V 240 V, 1-phase, CSA/CE/CCC
400 V, 3-phase, CE/CCC
480 V, 3-phase, CSA
0.99
0.94
0.93
Idle state power consumption
(CE systems)
230 V
400 V
17 W
23 W
Power source efficiency at rated
maximum output power
(CE systems)
230 V
400 V
90.3%
89.9%
R
sce
Short Circuit Ratio
(CE systems only)
U
1
–Volts AC rms, 3-phase
400 V, CE
R
sce
73
EMC emissions classification
CISPR 11 (CE models only)
***
Class A