Troubleshoot Common Problems
90 811470 Operator Manual Powermax45 SYNC
Cold restarts and quick restarts
To restart the plasma power supply, set the power switch
on the plasma power supply to OFF (O) and then set the
power switch to ON (I).
In some conditions, it is possible that you will be asked
specifically to do a “cold restart” or a “quick restart.”
Do a cold restart
1. Set the power switch on the plasma power supply to OFF (O).
2. Wait approximately 1 minute or until all of the amperage LEDs on the hand torch go off.
3. Set the power switch on the plasma power supply to ON (I).
Do a quick restart
1. Set the power switch on the plasma power supply to OFF (O).
2. Immediately set the power switch on the plasma power supply to ON (I).
If a fault occurs while you are using a generator, a quick restart does not
always remove the fault. Do a cold restart instead.