Install and Set Up the Plasma Power Supply
2
Powermax45 SYNC Operator Manual 811470 37
Generators used with this system must meet the voltage requirements in the table below and in the
Hypertherm plasma power supply ratings on page 19.
Adapter for 4-wire 1-phase connections (CSA 1-phase models only)
A 4-wire 1-phase connection (for example, NEMA 14-50R) is necessary for some generators. In
this condition, use an adapter to connect the plasma power supply’s 3-wire power cord plug
(NEMA 6-50P) to the 4-wire connector on the generator. Refer to Prepare the power cord and plug
on page 35 for more information.
Connect the gas supply
Engine drive rating
Plasma power supply
output current
Performance (arc stretch)
10 kW 45 A Full
8kW 45A Limited
6kW 30A Full
WARNING
EXPLOSION HAZARD
The filter bowl in the plasma power supply can explode if the gas pressure is more than
9.3 bar (135 psi). Never use more than the maximum gas pressure of 9.3 bar (135 psi).